Common array manager.

Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …

Common array manager. Things To Know About Common array manager.

“Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release Notes2. Instructions to download Common Array Manager (CAM). Method 1 - Searching with the MOS patch number: Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download.Sun Storage Common Array Manager provides several storage profiles that meet most storage configuration requirements. By default, the New Volume wizard will allow you to select a default pool with its default profile of RAID-5 characteristics. The profiles that display are specific to the model of the array and the drives it supports.1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …Applying Solaris patch 147416-02 (sparc) or patch 147419-02 (x86) to Sun Storage Common Array Manager (CAM) version 6.9.0 may cause registered arrays to present an alarm stating that out-of-band (oob) communication has been lost, and report the health status of the array as "Lost Communication"

Sun Storage Common Array Manager Installation and Setup Guide Administration, configuration, and monitoring Online help integrated with the software. Customer and field replacement procedures Service Advisor integrated with the software. Reference information for the CLI Sun Storage Common Array Manager CLI Guide sscsman pagesThese release notes cover the software released on the Sun StorageTek Common Array Manager Software 6.0.0 CD. The Release Notes consist of the following sections: Features in This Release

xii Sun StorageTek Common Array Manager Software Installation Guide • January 2007 How This Book Is Organized Chapter 1 provides an overview of the Sun StorageTek Common Array Manager software and installation process. Chapter 2 describes how to install the Common Array Manager software and the local and remote host …Common Array Manager alarm code xx.66.1040: A controller cache backup battery has failed. Refer to <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, 6000 and J4000 Arrays. Changes. No changes have occurred on the array, other than the automated …Goal. If you want to install Sun Storage Common Array Manager (CAM) in a Solaris 10 non-global zone, you first need to install Lockhart/Java Web Console in the Solaris 10 global zone, otherwise the installation of CAM fails with one or more of the following errors:It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).

Sun StorageTek Common Array Manager Installation Software CD 提供了三个与安装 有关的向导:. GUI (Graphical User Interface,图形用户界面)软件安装程序 - 使您可以通过图 形用户界面向导安装一系列选定的应用程序,以支持本地或远程的管理主机。. CLI (Command-Line Interface ...

Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.

Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …Jun 12, 2019 · This article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of ... Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Symptoms. Common Array Manager (CAM) is generating an alarm for a fault against one of its registered arrays. CAM fails to report the appropriate description and grid code for the alarm. The details may look …Adding New Users and Assigning Roles. Creating Host Accounts. To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage.Sun Storage 2530-M2 Array - Version Not Applicable and later All Platforms Goal. This document describes the significance of a volume's "owning controller" and "preferred controller", and also explains how to change the "owning controller" setting of an individual volume via the Sun Storage Common Array Manager software.

xii Sun StorageTek Common Array Manager Software Installation Guide • January 2007 How This Book Is Organized Chapter 1 provides an overview of the Sun StorageTek Common Array Manager software and installation process. Chapter 2 describes how to install the Common Array Manager software and the local and remote host …See your Sun StorageTek Common Array Manager Software Installation Guide (part number 820-4193) or Sun StorageTek Common Array Manager User Guide for the J4000 Array Family (part number 820-3765). 5. Log in as root (Solaris and Linux) or as a user with administrator privilege (Windows) on the management host. 6.To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage; guest; User names must be a currently defined user on the management host.The SAS expander on the Multi-Fabric NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which …Common Array Manager alarm code xx.66.1040: A controller cache backup battery has failed. Refer to <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, 6000 and J4000 Arrays. Changes. No changes have occurred on the array, other than the automated …Sun Storage Common Array Manager provides several storage profiles that meet most storage configuration requirements. By default, the New Volume wizard will allow you to select a default pool with its default profile of RAID-5 characteristics. The profiles that display are specific to the model of the array and the drives it supports.SANtricity or Common Array Manager report a critical fault of Host IO Card has Failed (xx.66.1150). SANtricity or Common Array Manager report a critical fault of Host IO Card is Degraded (xx.66.1300). SANtricity or Common Array Manager reports a critical fault of One or More Volumes not on their Preferred Path (xx.66.1010).

Overview. Sun StorageTek (TM) Common Array Manager is a Shareware software in the category Desktop developed by Sun StorageTek (TM) Common Array Manager. The latest version of Sun StorageTek (TM) Common Array Manager is currently unknown. It was initially added to our database on 10/30/2007.

The Sun Storage Common Array Manager (CAM) 6.10 release is available only for Solaris OS management hosts. CAM 6.10 for Linux and Windows hosts is in development and will be available once it is complete. Until then, continue to use CAM 6.9 for Linux and Windows, which is available from My Oracle Support (MOS) https://support.oracle.com.Feb 21, 2023 · This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component ... Setting Up Notification for Fault Management. The fault management features of Sun Storage Common Array Manager enables you to monitor and diagnose your arrays and storage environment. Alarm notification can be provided by: Email notification Simple Network Management Protocol (SNMP) trapsSee your Sun StorageTek Common Array Manager Software Installation Guide (part number 820-4193) or Sun StorageTek Common Array Manager User Guide for the J4000 Array Family (part number 820-3765). 5. Log in as root (Solaris and Linux) or as a user with administrator privilege (Windows) on the management host. 6.It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose … 使用 GUI 管理阵列 《Sun Storage Common Array Manager 阵列管理指南,版本 6.9.0》 使用 sscs CLI 管理阵列 《Sun Storage Common Array Manager CLI Guide, Version 6.9.0》 故障排除信息和硬件更换过程 服务顾问,从 Sun Storage Common Array Manager GUI 启动 从固件版本 6.x 升级到 7.x “升级固件 ... Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Purpose. This document lists the open ports required on a management host in order for Sun Storage Common Array Manager (CAM) to function properly. DetailsDell OpenManage Array Manager, v.3.6.0.568.5, A05. Array Manager software provides a comprehensive storage management solution in an integrated, graphical view. From a single location, Array Manager enables you to configure and manage local and remote storage attached to a server, while the server is online and continuing to process requests. To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software.

The intent of this document is to explain how to download Common Array Manager (CAM) and its patches from My Oracle Support (MOS) - Patches & Updates. The 3 steps are: …

Sun Storage 2530 Array - Version Not Applicable and later Sun Storage 6180 Array - Version All Versions and later Sun Storage 6580 Array - Version All Versions and later All Platforms Goal. This document reviews the procedures for collecting performance statistics from arrays that can be managed using Sun Storage Common …

使用 GUI 管理阵列 《Sun Storage Common Array Manager 阵列管理指南,版本 6.9.0》 使用 sscs CLI 管理阵列 《Sun Storage Common Array Manager CLI Guide, Version 6.9.0》 故障排除信息和硬件更换过程 服务顾问,从 Sun Storage Common Array Manager GUI 启动 从固件版本 6.x 升级到 7.x “升级固件 ... Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest. Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another (6.x to 7.x) requires a utility specific to the array family.The Program calculates the sets, rises and phases of the sun and moon... The HPE Smart Storage Administrator (HPE SSA) is a web-based application... Trusted Windows (PC) download Sun Storage Common Array Manager Online Help 6.9.0.16. Virus-free and 100% clean download.Note - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 …This article documents Sun Storage 6580/6780 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Look for the StorageTek Common Array Manager (CAM) Software release 6.1.2 or later. Using CAM With Disk Blades and Virtualized Multi-Fabric 10GbE NEM. CAM provides both a browser and command-line interface. When using the browser interface, you set up user accounts. When an authorized user logs in, information is laid out in pages.Hi! I have Sun StorageTek 2540 FC array and CAM works very slowly - I can wait for software response even more than 2 minutes... I run this software on Windows machine with Firefox Web Browser but spe | The UNIX and Linux ForumsJun 4, 2023 · This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware ... 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.

Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Purpose. The purpose of this document is to help troubleshoot the Sun Storage Common Array Manager (CAM) login problem that produces the error:Sun Storage Common Array Manager (CAM) - Version 6.1 to 6.10 [Release 6.0]: Sun Storage Common Array Manager (CAM): Connections Refused with Error "ERR_SSL_WEAK_SER Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).For the Sun Storage J4000 Array Family, refer to the Sun StorageTek Common ... Mar 9, 2022 · Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application. Instagram:https://instagram. teamp numberremembetterme workoutssfo to spain This document is designed to help clarify when a drive should be replaced, if this fault should be present on an array. Symptoms Include: SANtricity Storage Manager shows an alert for Impending Drive Failure Low Risk; Common Array Manager shows an alarm for Impending Drive Failure Risk Low (xx.66.1026)Array Technologies (NASDAQ: ARRY) has surpassed Wall Street projections four times, including the last quarterly EPS of 21 cents per share, 91% higher … terrebonne quebecnovelas gratis Storage Common Array Manager 6.8.1. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1 my metro en espanol It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400). viSun StorageTek Common Array Manager 软件安装指南• 2008 年 10 月. 查找文件和日志 11 安装命令汇总 13 从远程终端安装(Solaris 和 Linux) 13 在 Solaris OS 上安装 14 在 Solaris OS 上使用 GUI 进行安装 14. 安装软件(在 Solaris 系统上):15 在 Solaris OS 上使用 CLI 进行安装 19. 使用 ...